Model 803E

Download the brochure

CO2/O2 Analyzer

The NEW 803E uses the proven paramagnetic O2 measurement principle, coupled with a state of the art CO2 NDIR sensor.

These are combined with the TAPI E series advanced microprocessor based electronics to provide a high performance analyzer giving accurate, dependable measurements of percent level Oxygen and Carbon Dioxide. This combination product is ideally suited for measuring extractive source emissions, and both paramagnetic O2 and NDIR CO2 are reliable tools used extensively for RATA’s. The 803E provides a cost effective solution for both markets.

All TAPI E-Series include an extensive built-in data acquisition capability using the analyzer's internal memory. This allows the logging of multiple parameters including averaged and instantaneous concentration values, calibration data and operating parameters such
as flow and pressure.

Stored data are easily retrieved through the serial port or optional no-cost Ethernet port and viewed via our APIcom software or from the front panel, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends. The Model 803E combines light-weight, rugged construction, ease of use, powerful diagnostics, modular design and outstanding performance to yield the ideal tool for today’s air monitoring requirements.

Features

  • Standard two year warranty
  • O2 Range 0-100%, CO2  Range 0-20%
  • Microprocessor controlled for versatility
  • Multi-tasking software allows viewing test variables while operating
  • Continuous self checking with alarms
  • Dual bi-directional RS-232 ports for remote operation (optional RS-485 or Ethernet)
  • Digital status outputs indicate instrument operating condition
  • Adaptive signal filtering optimizes response time
  • Temperature & Pressure compensation
  • Critical orifices provide flow stability

Specifications
CO2
Ranges: 0-20% CO2
Zero Stability: < 0.1% CO2 in 24 hours
Span noise: < 0.1% RMS CO2
Span Stability: < 0.2% CO2 in 24 hours
Accuracy: 1.5% CO2 of range + 2% of reading
Linearity: < 0.5% full scale CO2
O2
Ranges: 0-1% to 0-100% user selectable O2
Zero Stability: Short Term: < 0.1% O2 in 24 hours 
Long Term: < 0.2% O2 in 7 days
Span noise: < 0.05% O2
Minimum Detectable Change (MDC):  < 0.1% O2
Linearity: < 0.1% O2
Repeatability: < 0.01% O2
Minimum Detectable Change (MDC):  < 0.1% O2
Lag time: 10 seconds
Rise and Fall Time: < 60 seconds to 95%
Linearity: < 0.1% O2
Repeatability: < 0.01% O2
Sample Flow Rate: Max/Min 130ml ± 20ml/min
Operating Temperature Range: 5 - 40˚C
Humidity Range: 0-95% RH
Pressure Range: 25-31 in Hg
Dimensions (HxWxD): 7” (178 mm) x 17” (432 mm) x 23.5” (597 mm)
Weight: 28 lbs (12.7 kg)
Power: 100V - 120V, 220V - 240V, 50/60 Hz
Analog Outputs: 10V, 5V, 1V, 100mV, user selectable
Recorder Offset: ±10%
Serial Outputs: Format (RS232/485, Ethernet, Multi-drop)
One RS-232 port (DB-9 male), one RS- 232 or    RS-485 User Selectable (DB-9 female)
Status (Digital): 8 outputs, 6 inputs (opto-isolated), 6 alarm
outputs (optional)
Current Output: Optional 4-20mA, select up to three channels


   