List All Warning Messages:
Test values:
ParameterObserved valueUnitsNominal Range
Range PPM 1 - 1000 PPM
Stabil PPM <=0.05 PPB with Zero Air
CO MEAS mV 2500 - 4800 mV
CO REF mV 2500 - 4800 mV
MR Ratio   1.1 - 1.3 w/ Zero Air
Pressure In-Hg-A -2" Ambient Absolute
Sample Flow CC 800 ± 10%
Sample Temp °C 48 ± 4
Bench Temp °C 48 ± 2
Wheel Temp °C 68 ± 2
Box Temp °C Ambient +7 ± 10
Photo Drive mV 250-4750mV
Slope   1.0 ± .3
Offset   0± 0.3
Dark Ref mV 125 ± 50 mV
Dark Meas mV 125 ± 50 mV
ETEST PPM 40 ± 2 PPM
Values are in the Signal I/O
REF_4096_MV mV 4096mV ± 2 mV and Must be Stable
REF_GND mV 0±0.5 and Must be Stable
What is the sample flow and sample pressure with the sample inlet on rear of machine capped?
Sample Flow: CC Sample Pressure: in-Hg-A
Please check these signals and verify the correctness.
Look for the signals annotated on the diagram. What are the peak-to-peak voltages?

Can you fax a portion of the strip chart pertaining to the problem? Circle pertinent data.
Enter code to confirm submission
Validation Enter Confirmation Code:    *
 



Home | Terms of Use | News & Events
e-mail us: api-sales@teledyne.com

Teledyne is an Equal Opportunity/Affirmative Action employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, pregnancy, national origin, age, disability, protected Veteran status, or any other characteristic protected by applicable federal, state, or local law. EEO Is The Law.

If you need assistance or an accommodation while seeking employment, please email teledynerecruitment@teledyne.com or call (805)373-4545. Determinations on requests for reasonable accommodation will be made on a case-by-case basis. Please note that only those inquiries concerning a request for reasonable accommodation will receive a response. Teledyne participates in E-Verify (English) (Spanish) and Pay Transparency. Details on Right To Work may be found in English and Spanish.

To confirm the authenticity of any recruitment related correspondence, please email teledynerecruitment@teledyne.com or call (805) 373-4545.

Copyright © 2015 Teledyne Technologies Incorporated. All rights reserved.
Teledyne API • 9970 Carroll Canyon Road • San Diego, California 92131 • USA